We are on our third timer. If you find no answers readily apparent, then replace the timer mechanism they dont last forever! To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward. I can, however, hear an intermittent click as if the mechanism is trying to switch on. Replaced timer motor on a T10404R Now time is running fast about 2 hrs. Clean the gears with a toothbrush if you see debris or gunk in them. If the pump doesnt come on, follow the steps below. With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. Some white lithium grease on the switch can help in some cases. I see that the Intermatic WG1573-10D Replacement 208-277 VAC, 60 Hz Motor, is compatible with For use with T102, T104 and WH40 clocks by Intermatic. Other than a couple of weeks, we have spent fifteen years manually turning on our pump. "@type": "ImageObject",
Thank you. Terminal A (farthest to the left side) is not connected to anything. Put a meter on the wires or trace them back to find out their voltage and source. Thanks! Monday the clock face was free spinning, today when I got home it had broken and fallen off. Same goes for slipping timer dogs! Replace the plastic insulator cover, turn on the power, and observe the visual motor check. If you look closely, you should be able to discern if this is the problem, which could mean a new clock. Maybe 2/wks ago I replaced it with a new timer, and it's doing the same thing. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . Im going to try inspecting the back of the timer to see if a wire go knocked loose or something. I have an Intermatic t104. If you cant see an issue with the gears, then it could be the timer motor. If the trippers are set for on and off pump function and nothing is working, reset the time and trippers. OPEN TODAY, 12PM TO 3PM. The clock not turning on your Intermatic pool timer is a common issue. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. Hi Davy, Thanks in advance! The problem lies, where the power dies, as they say, Thanks for the response. Hi Jeff, it could be that the terminals in the rear of the clock mechanism are fuse-welded together, and not separating like normal, when the on/off switch is flipped. My timer clock does not run and the manual on off switch does not turn off the pump motor. Gently tighten the screws to securely hold the dogs in place. Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. Any help is greatly appreciated. my pool timer the does not turn itself on only shuts off I put new trips in but still not working I dont see any ant build up inside there or anything could it just be time to replace the old girl because thats what Im thinking. If your 120V wires are properly colored, the White wire connects to terminal A, and the Black wire connects to terminal 1. When I put the new one on, the trippers do not work. Keeping a pool operational is expensive enough anyway, so every saving you can make helps. Hi Jere, that could be the timer motor failing. I looked to see if the gears on the timer are running. Your pool timer and pump will be on its own circuit and have a dedicated circuit breaker or GFCI (ground fault circuit interrupter). Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . Hello. Also be sure that the ON dog is not actually an OFF dog, and that it is tightly secured to the dial edge and pushed all the way onto the dial, and straight. It only takes a small amount of dirt to foul up gears so look carefully. Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. If the motor or wires are faulty in your Intermatic time clock, its time to replace the mechanism. For Do-it-Yourself pool owners like yourself to make simple,, Sure, you could just replace your entire Hayward pump, but replacing only the motor is just as easy, and you don't have, Millivolt Pool Heater Troubleshooting Guide, https://www.intheswim.com/p/2-circuit-pool-timer, https://www.intheswim.com/p/24-hour-pump-timer, https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf. So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. Hi there, Flip off the breaker. Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. If you cant, is the manual switch stuck or jammed? I called Intermatic and there is nothing you can do except check it every time you have a power loss. Ft. 750 Joshua Dr, Hollister, CA 95023. Check that the motor gears are still moving also, when it gets to the switch and the dial stops moving. "caption": "In The Swim Blog"
For additional tripper pairs on CLOCK-DIALorder 156T1978A. 4 Beds. The clock is powered from the Line 1 terminal correct? More. I have a sweeper set on auto on the second timer and it is working correctly.
Save my name, email, and website in this browser for the next time I comment. In this article, well cover what problems you may find with your Intermatic timer and how you can fix it without having to run to the store. I have a T103 24 hour dial time switch and noticed the time was off so not reading the DO NOT UNSCREW on the pointer I unscrewed it and moved the pointer to the right time and screwed it back tight. It is not warped in any way. Any ideas why its doing that? Im sure I hooked it up correctly but when running it gains a little over an hr of time every 24 hours. Hi Rhomell, are you sure you got the correct trippers? It is generally not recommended to reuse a critical fastener like the rear spinal nut on your 2000 Ford Focus. Thanks. My original timer worked for 5 years then the clock stopped and I heard no sound. Terry, unusual but check all connections, making sure that bare wire is tightly contacting the terminal screw plates. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. },
Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts Replacement for T100 Series and Intermatic Time Clocks T101, T102, T103, T104, Pool Timer On Off Clips(4 ON / 4 Off / 8 Screws) : Amazon.com.au: Home Improvement Also be careful not to loosen the timer pins to much or they could fall off the timer wheel and onto the ground. Not sure if you still answer these but I have a weird one for you. Thanks in advanced. I mean you could go out and buy the timer for the electrician but you will need his experience to get it installed correctly. It is an ON tripper right? You will first need to adjust the time on the timer first. Thanks for any help you can give. These clocks determine when your pool pump turns on, and how long it runs. by pool co. , so wondered about the cost. },
See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. I had the exact same thing happen recently. I have a 2 speed pump. {
So if you see the 10am behind the time marker, this means that the timer has the current time of 10am. 1. Now, Im going to order some additional timer clips. Hi Rich, is one of those wires (white?) How can I fix this? And there you have it, the quick and easy ways to troubleshoot common Intermatic pool timer problems. A timer replacement would be required. I flicked the switch between on and off and it will not shut off. I have replaced the trippers, but the problem persists. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. You should always be able to switch your pump on and off manually at the timer. Hi Peter you say that clock is seated correctly, and I assume you mean that the dial is pushed in, or the gear on the back of the dial is engaged with the turning gear. Found the answer. They may be fused together, or could be a lizard stuck in there, or some other foreign object or insects. Take them off and inspect them and look for twists in them. Check the wiring also, looking for broken wires or loose connections, which could explain the breaker tripping as well. When you flip the switch does it separate and reconnect the tabs? Hi Carlos, is there a GFCI outlet in the circuit? I have a PF1112T. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. Thank you so much. Repeat the process for the "on" pin. I hope this helps. My pool timer is in the off position and it is still running. be sure the pins are pushed onto the edge of the dial fully. Take them off and inspect them. "url": "https://intheswim.com/",
Any suggestions? The timer appears to be working fine (keeps time). Any suggestions as to how to test clock feed? The timer quit after a nearby lightning strike. Just moved into my house and the pool pump continues to run even after tripping the timer mechanism. If its not, it wont work properly. Turn on / off manually work fine, but The clock gears still not moving. Sometimes you will find the timer appears to be working, that is the clock dial is turning and you can see the gears behind the clock turning, but the pump isnt being switched on or off. Push down on the timers until they snap into place. . This is hard to check if you are not qualified. If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. Why it always stop around 10pm by itself and not moving again? Or if power is interrupted to the pool pad, for some reason, maybe breakers flipped off for some electrical work? Put them back on and tighten them. Analog timers are the simplest type of pool pump timer and are easy to use (and the cheapest). I noticed that the on flipper was a little bit bent so I replaced it with new one. ft. 975 Telegraph Rd #103, Santa Paula, CA 93060 $409,000 MLS# V1-15365 Hillview Estates, where you own the land, and this one has a big lot, over 4,100. Then turn the breaker, that the time clock is connected to, off and back on again. Also known as an RCD (residual current device) in Australia and the UK. With the power switched off at the breaker, take out the main part of the timer and carefully inspect the gears for obstructions and missing teeth. Not sure if i need to check out the wiring, but it is a bit frustrating. Move the switch and see that they separate when off, and come together when on. For example, sometimes you can see a burnt wire or sometimes it may be as simple as the circuit breaker has been tripped. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. I have replaced my pool timer 3 times in the last week and they will work for a day then quit working any idea what the problem could be? You may need to adjust the meshing of the timer motor gear so it runs the clock. The instructions say THIS TIMER IS NOT TO BE USED AS A POWER DISCONNECT. If it continues and cant find solution, suggest replacing timer motor, or entire mechanism. So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. So what you will want to do now is to look for the circuit breaker panel and locate the circuit breaker for your Intermatic Pool Timer and then make sure it is set to the on position. Sometimes during power surges or lightning, these will be fused together and not come apart. Hi, new timer out of the box, 200V. Pools are not cheap! No broken or loose wires visible. PF1202T Freeze Protection Control Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control I manually turn it on timer is running, it will trip pump OFF. The circuit is protected by two ganged breakers. Have you any suggestions at to why I am experiencing this problem? the timer was directly plugged into a gfci and the pump directly into the timer. Perhaps you had a power outage during the night? The timer seems to get stuck prior to reaching the on trippers therfore the pump cant turn on. It loses about 1.5 to 2 hours per day without any outages. "@type": "ImageObject",
Other problems causing this could be the yellow clock dial isnt located correctly, wiring is loose, the gears are stripped, damaged or partially jammed or even the clock motor. The capacitor for the motor may be bad. My pool pump and skimmer are on two different motors. NEW CONSTRUCTION. Sometimes bugs get in there and jam the gears, sometimes debris is the issue and other times the gears get old and may lose a tooth. If you dont have the voltage here you have an issue with either the wiring or the breaker. by Intermatic Technical Support | Jul 25, 2022 Helpful? South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveler reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. Second thing to check is the dial bent or warped, in that area where the on tripper is? sometimes Im forgetful lol what are your thoughts? Hi, Related Reading: Should You Get a Pool Pump Timer? The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. There is power; gears are moving. Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. If your pool pump timer is beyond repair, call a professional to replace it. You will feel the wheel pull out about an 1/8 of an inch and then you will be able to rotate the timer wheel. Hi Andy, when a clock is running slow, we might assume power outages, but when it runs fast, we might assume either a 60 hz (US) timeclock hooked up to 50 hz power service (Europe), or vice-versa, or a manufacturing defect in the gear tolerances could cause a synchronous motor timer to run fast. I can manually turn it on with the lever at the bottom. Basically youre eliminating possibilities until you find the cause. Also be sure that the front dial is engaged with the gear located behind the dial. Should it still not work, I suspect a motor failure for the clock. Reasons Why Pool Timers Stop Working 1. Welcome to Pool Spa Outpost! This site is owned and operated by AJH Trade Group. Replace them if they appear to be bent. i have a P1121 intermatic timer connected to a hayward above ground pool pump. Also check that the motor number is compatible with your clock model. The dial turns, but when it gets to the trippers, both now, the dial stops & there is no sound the gears are working I am not an electrician but I can do small repairs. And does the switch look worn, where the tripper engages? Thanks. Any suggestions? You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. I have changed the dog tripper and that does not take care of - Answered by a verified Electrician . HELP! Theres an issue with the wiring between the circuit breaker and the timer. We recommend these Intermatic timers for most pools:Intermatic T101 Intermatic T103Intermatic T104Intermatic T103. I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. May we present Speed Tripper, the second pedal collaboration from Death By Audio and LEVITATION. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. It just seems to have a weak start?? how should I lubricate those? I took the electrical box cover off and check the breaker connections. I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. },
If you are not sure if your timer is working or not you will first need to know if its even operational. They are: Heres how to troubleshoot a mechanical pool timer step-by-step: It goes without saying that you should be qualified if you intend on working with live power. Black goes to _1 Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. I have three outlets going out one to the pump , one for the salt system and one for the GFCI outlet. No high loop or air gap in the old under-the-sink dishwasher drain, Consider radiant underfloor heating system, Several Important Steps Homeowners Can Take To Protect Their Furnace, 4 Kinds Of Chemical Drain Cleaners That Clear Out Drains and Their Hidden Dangers. The power should run from the breaker, to the timer, to the pump. Hi Catherine, turning it on manually should not have damaged anything, so go easy on yourself It might have just been time to go. Timer not tripping pump on. Or be loose and not making good contact. You can find this in your power board. You can turn off Freeze protection and it should stop, or replace the probe if faulty. I bought a new motor for mine after 20 years and learned about this the hard way. Elite. Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. Electrical Monke Aug 25, 2021 #22 It's broken. Now remove the terminal cover on the timer. So either the tripper is broken (or installed out of alignment) or the tab (s) on the on/off switch are broken. "caption": "In The Swim Blog"
It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. Or might find something else. Refer to the wiring diagram on the timer door for more information. My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. Your email address will not be published. Did you find the issue? Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. I looked through the visual motor check and the gear still moving fine. During this the pump cannot be manually switched on. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
To adjust the time you will first want to look for the time bar that is mounted in the middle of the timer wheel. Now Im having to turn my pool pump on and off manually. The terminals on the wires aren't tight. "@type": "BlogPosting",
You can replace it but its really just easier to replace the entire mechanism. Eldon, the breaker should not be bad, but the timeclock may be wired incorrectly. Please advise. You can replace the timer motor only, or the entire clock, both fairly easy to swap out. I tried to change the on tripper due to Daylight savings time & dropped the screw. The old "off" tripper was fractionally bent. If your Intermatic swimming pool timer has stopped working you will have to do something called troubleshooting. Start with the easy checks. I not sure if this is the best timer to use. Hi, hope you are doing well. Is it toast ? This div height required for enabling the sticky sidebar. Thanks for the suggestions.. Hi Davey, i would like to use a timer but am now afraid to try another. Ive seen it happen from lightning strikes, or insect infestation. The pump worked perfectly before I unscrewed it. I guess if they look the same as before maybe the dial is warped? Gold OFF tripper works for all models. As it get cooler you can cut it down to 5 or 6 hr a day . }
. Why do we stock so many pool parts? If there has been a recent power outage, the clock will have stopped and youll need to reset the clock to the correct time. . Open following links to identify timer and then add a comment. Shannon, compare the wiring to the diagram for Line and Load (line is power coming in, Load is power out to your pump). DEWENWILS Pool Pump Timer, Outdoor Smart Wi-Fi Box, Heavy Duty 40A 120-277 VAC 2HP Wireless Controller Timer for Pool, Water Heater, Compatible with Smart Phone, Alexa, Google Assistant, UL Listed. Intermatic time clock motors can be replaced, but unless the time clock is brand new, its best to replace the entire Intermatic mechanism. Does this mean I need a new T104, or is there a replacement manual on/off switch? Hi, if you have a variable speed pump, you do not need to use the external timer anymore, but should program with the on-board pump timer. This will disengage the dial and allow you to spin it in either direction. Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. If I manually flip the switch nothing happens. Electricity is dangerous and can kill you if you dont know what youre doing. After securing the wire conduit (flexible or rigid) to the box, knock out with the proper 3/4 conduit connector. Do you have an answer to why my pump wont turn off or on? It is a mechanical issue between the trippers and the switch lever. Common timer problems include the clock not turning, not switching the pump on/off, loose timer pointer and a stopped clock. If so, is there power coming into the clock (on the line terminals)? We had a few power outages the last couple of weeks, but Ive reset the time and it continues to lose time. Hi John, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. Hi DavyI just installed a new timer after being told by the pool inspector that the old one was dead. All Rights Reserved. The tripper will not move. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. So what would be the problem? Use a power meter set on AC volts to verify the power is off, before handling the timer mechanism. You will have live wires exposed and they can kill you if you touch them. Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer 4. ), you should be able to discern if this is the problem, which could mean a new clock. It stays on until I turn off the circuit breaker. "primaryImageOfPage": {
not sure what is the problem. on two occasions the plug from the pump almost melted and the second time the pool pump plug had to be replaced and i discontinued using the timer and disposed of it. Could also be grit or insects inside of the gears of the clock motor. I would shut off power to the clock while you spray, and release the tab at the top so you can spray behind the clock, and then find the nearby nest, and dig it up and add in some ant killer granular, or other method, to get the colony to move somewhere else. My Polaris booster pump ONLY turns on via the trippers. Timer dial is not turning Breaker OFF Turn ON Power Timer motor dead due to lightning Replace timer 3. Hi, Davy, seeing lots of complaints here. AJH Trade Group Australia Pool Equipment | Pool Lifestyle | Pool Heating | Pool Maintenance | Pool Problems, what to do when the pump circuit breaker continually trips. It I set the timer again it will jeep time until it gets to the next dog ear. Replaced complete new timer assuming 5 years perfect service probably wore it out. Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. It just stays at that time. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Motor runs past the on dog but doesnt flip pump on? Your incoming power leads should connect to terminals 1 and 3, and the wires that lead to the pump, should be connected to terminals 2 and 4. Homes similar to 2425 Glenview Dr are listed between $725K to $2M at an average of $385 per square foot. When I turned it back on now the pool clock goes backwards. If soft, it may not be fully engaging the switch, which is (sort of) visible next to the tab. Elite Swimming Pools TV 4.08K subscribers Subscribe 1.1K Share 97K views 3 years ago MIRAMAR Pool timer. Only perform this step if you are qualified. Clock not turning or making any sound. Help! "datePublished": "1/10/2020",
I have the PF1202T timer on my pool. They are little ants that just came. But the next morning it wont engage by itself again, it seems it sticks when getting to the point its supposed to flip on. You could spray some light lubricant like WD-40 or 3-in-1 oil onto the gears both for the motor and behind the dial. Simply screw it back into place until its snug. If power is coming to the timer motor, you will clearly see the gears moving through the small window. i have an oval pool that is closed for the winter but there ha been a problem. "mainEntityOfPage": "https://blog.intheswim.com/intermatic-pool-timer-troubleshooting/",
We may earn a small commission. We have a comprehensive article that covers what to do when the pump circuit breaker continually trips. If its loose, grab a screwdriver and tighten it up. No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. my pool cleaner timer dog is set between 8 am and 11 am, everything is working fine manually, except that the pool cleaning pump will not start by the timer dog setting the clock is set correctly and moving . Is the timer repairable, or should I just install a new one? Hi, then the power for the clock must be from the switch, and not from the breaker? With this model can I control both of these motors with two different on and off times. the trippers are even slightly damaged the timer won't work correctly. If I manually push the lever, it moves without much pressure. Since you have another switch in between the breaker and clock, the breaker will lose power when the switch is turned off. The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing. Everythings OK now, unit works just fine. Hello. These nuts are designed to provide a precise amount of clamping force and ensure proper alignment of the rear suspension, so reusing them may compromise the safety and performance of your vehicle. Flip it from where it is now, to the opposite side. I have heard that perhaps a run of mis-marked motors went out and you may have a 50 Hz actually. Move the start and stop pins to appropriate times for swimming pool filter operation. Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). Terminals 2 and 4 are used for wires going to the load (pump). So out comes the soldering gun and the shrink wraps and that did the trick. Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. Hi Bev, seems legit to me! Hi Tyler, maybe the dial is now pushed forward, far enough to where the trippers do not contact the switch? Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. Any thoughts before I run out to replace it? Replace a new T104. Ill do the same. Leave the paper inside your timer box so that you do not mistakenly misplace it. If the trippers are loose, then they could slip and cause issues with the pump turning on/off at the correct times. "
The gears in mechanical timers can get damaged. Is it Necessary? I realized today that my pump has been on for 11 hours, but the clock has only moved a few hours. If youve followed this guide or arent confident in diagnosing the issue yourself, seek a qualified pool technician or electrician. If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. GFCI breakers trip at a very low threshold, doesnt take much. I have removed the ON TRIPPER and turn the motor on at the pump and it never trips the GFCI.